Cal 9900 temperature controller pdf

 

    CAL AUTOTUNE PID TEMPERATURE CONTROLLER features covered in this manual. View set point . instructions now entered in memory. AUTOTUNE PID TEMPERATURE CONTROLLER. INSTALLATION The CAL microprocessor based temperature . instructions now entered in memory. The CAL microprocessor based temperature controller provides precise control with a minimum of setting up, the advanced Autotune algorithm tunes all.

    Author:ALINE HOKAMA
    Language:English, Spanish, Portuguese
    Country:Mongolia
    Genre:Science & Research
    Pages:631
    Published (Last):19.05.2016
    ISBN:857-1-71096-357-8
    Distribution:Free* [*Registration Required]
    Uploaded by: TARYN

    52743 downloads 150914 Views 14.43MB PDF Size Report


    Cal 9900 Temperature Controller Pdf

    View and Download CAL Controls CAL installation and operating manual online. Autotune PID. CAL Temperature Controller pdf manual download. Distributed by: M&M Control Service, Inc. mechutatype.cf Page 2. Distributed by: M&M Control Service, Inc. Temperature Controller Troubleshooting Guide (Press the P button and the controller will say 1 or The 0 will If no success contact CAL or attempt manual tuning. Carefully remove the A board from the output module and case.

    Item Description V1. Thank you. ShippingWe do not ship to P. International customers are responsible for all duties, taxes, and tariffs. There will be no refunds for refused shipments. Please note that shipping charges are estimated and do not take into account multiples, oversized packages or insurance. We estimate shipping costs in order to keep shipping cost as minimal as possible. Actual shipping charges will be calculated and added when your order is processed. If there is a significant increase in shipping, your order will be held and you will be contacted. We apologize in advance for any inconvenience this may cause you. We do our best to accurately describe the items that we are selling. If you have any questions or problems with your transaction please contact us as we strive for customer satisfaction. The photos that are provided are of the actual item, unless otherwise stated in the description. Please take the following into consideration.

    CAL Temperature Controller. For detailed instructions on using your projector in a network environment, see the EasyMP Network The meter enters the CAL mode and blinks the display of the In calibration status.

    CAL 1/16 DIN Temperature Controller (Single Loop) | Tempcon Instrumentation

    Note: -Factory preset ppm. CAL komplettes Benutzerhandbuch-Deutsch. CAL Manuel complet-Francais Manual 1. Manual 2.

    Manual You, as the end user, are legally bound EU Battery ordinance to return all used batteries The alarm range is from to ppm. When the Instruction Manual ; of important operating and maintenance servicing instructions in the literature accompanying CIP messages.

    Make sure that the input sensitivity of the two amplifiers is equal or that. This manual contains operation and maintenance instructions for Magna-Power Table of Contents Epson Stylus Pro , , , , , ,. Control can be optimised with a single shot autotune either on initial warm-up or at setpoint.

    A programmer offers a single ramp to setpoint with a choice of timed soak period before switching off the output. Control of non temperature processes is achieved by the provision of linear input ranges and scaling in commonly used engineering units.

    The results are measured and used to calculate optimum PID values which are automatically entered in the controller memory.

    When the above information has been programmed into the controller it will be operational with the following factory PID proportional band, integral time, derivative time settings. The cycle-time requires manual acceptance unless pre-selected.

    CAL Controls CAL 9900 Installation And Operating Manual

    The TUNE method normally achieves the best results. Starting with the load cool, tuning occurs during warm-up preventing overshoot.

    This method of tuning is recommended. During the tuning cycle some overshoot occurs because the tuning cycle is at set point.

    CAL 9900 1/16 DIN Temperature Controller

    The DAC setting is not re-calculated. A setting that is too long for the process will cause oscillation and a setting that is too short will cause unnecessary wear to an electro-mechanical switching device.

    Functions and options The facilities of the controller are selected from the multi-level menu using the front panel mounted buttons. It is advisable to study this section before any programming is undertaken.

    Cycle-time selection methods The following methods of cycle-time selection may be used: Note: Autotune calculated After Autotune has been run and completed the calculated cycletime can be manually accepted or adjusted to suit the switching device. For selection method see Select Autotune Calculated Cycle-time.